| 1.  Activate Fuel Cell Injector
 
| 1.  Activate Fuel Cell Injector
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|7}}
 
|-
 
|-
 
| 2.  Connect Fuel Cell to Bus2
 
| 2.  Connect Fuel Cell to Bus2
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|n}}
 
|-
 
|-
| 3.  Connect RCON-1 to Bus1
+
| 3.  Connect R-CON1 to Bus1
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|d}}
 
|-
 
|-
 
| 4.  Connect Bus2 to TRN
 
| 4.  Connect Bus2 to TRN
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|o}}
 
|-
 
|-
 
| 5.  Connect Bus1 to TRN
 
| 5.  Connect Bus1 to TRN
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|q}}
 
|-
 
|-
 
| 6.  Charge Reactor Containment to 2000As
 
| 6.  Charge Reactor Containment to 2000As
|style="background:#777777;" width=15%|{{key|}}
+
|
 
|-
 
|-
 
| 7.  Disconnect RCON-1 from Bus1
 
| 7.  Disconnect RCON-1 from Bus1
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|d}}
 +
|-
 +
| 8.  Activate Temperature View Mode
 +
|style="background:#777777;" width=15%|{{key|Tab}}
 
|-
 
|-
 
| LOOP
 
| LOOP
 
|
 
|
 
|-
 
|-
| 8.  Connect Reactor Heater
+
| 9.  Connect Reactor Heater
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|x}}
 
|-
 
|-
| 9.  Continue until Fuel Cell temp >= 110C
+
| 10.  Continue until Fuel Cell temp >= 110C
 
|
 
|
 
|-
 
|-
| 10. Connect BAT to Bus2
+
| 11. Connect BAT to Bus2
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|r}}
 
|-
 
|-
| 11. Continue until BAT temp >= 80C
+
| 12. Continue until BAT temp >= 80C
 
|
 
|
 
|-
 
|-
| 12. Disconnect Reactor Heater
+
| 13. Disconnect Reactor Heater
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|x}}
 
|-
 
|-
| 13. Wait until Fuel Cell Temp <=80C
+
| 14. Wait until Fuel Cell Temp <=80C
 
|
 
|
 
|-
 
|-
| 14. Repeat LOOP until Reactor Temp=80C OR Reactor Containment < 100As
+
| 15. Repeat LOOP until Reactor Temp=80C OR Reactor Containment < 100As
 
|
 
|
 
|-
 
|-
Line 69: Line 72:
 
|
 
|
 
|-
 
|-
| 15. Activate Reactor Injectors
+
| 16. Activate Reactor Injectors
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|5}}, {{key|6}}
 +
|-
 +
| 17. Disconnect Battery from Bus2
 +
|style="background:#777777;" width=15%|{{key|r}}
 
|-
 
|-
| 16. Disconnect Fuel Cell and Battery from Bus2
+
| 18. Disconnect Fuel Cell from Bus2
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|n}}
 
|-
 
|-
| 17. Deactivate Fuel Cell Injector
+
| 19. Deactivate Fuel Cell Injector
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|7}}
 
|-
 
|-
 
|}
 
|}
Line 84: Line 90:
 
|-
 
|-
 
| 1.  Connect Battery to BusA
 
| 1.  Connect Battery to BusA
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|F3}}
 
|-
 
|-
 
| 2.  Connect AYSE Reactor Heater to BusA
 
| 2.  Connect AYSE Reactor Heater to BusA
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|0}}
 
|-
 
|-
 
| 3.  Wait until Reactor Temp=80C
 
| 3.  Wait until Reactor Temp=80C
Line 93: Line 99:
 
|-
 
|-
 
| 4.  Activate Reactor Injectors
 
| 4.  Activate Reactor Injectors
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|[}}, {{key|]}}
 
|-
 
|-
 
| 5.  Disconnect Battery from BusA
 
| 5.  Disconnect Battery from BusA
|style="background:#777777;" width=15%|{{key|}}
+
|style="background:#777777;" width=15%|{{key|F3}}
 
|-
 
|-
 
|}     
 
|}     
 
==Physics==
 
==Physics==
 
Nuclear fusion is a high temperature process, and the reactor must be warmed before nuclear reactions can commence. As the reactions begin, it is essential that the reactors are shielded to prevent the astronauts from being irradiated. During the heating process, the reactor is unable to supply any power, so the fuel cell must be used to power both the reactor's shields and the heater.
 
Nuclear fusion is a high temperature process, and the reactor must be warmed before nuclear reactions can commence. As the reactions begin, it is essential that the reactors are shielded to prevent the astronauts from being irradiated. During the heating process, the reactor is unable to supply any power, so the fuel cell must be used to power both the reactor's shields and the heater.

Revision as of 22:56, 20 April 2010

Cold Starting is a term used to refer to the act of using the Fuel cell or Battery to heat up the Reactor so that it may be able to start reactions to produce energy. The steps to cold starting in the software are below.

Conditions

Cold start should be initiated under the following conditions:

Procedure

Permissions

Start

1. Open the Engineering Software
2. Select Cold Start c + Enter

Habitat

1. Activate Fuel Cell Injector 7
2. Connect Fuel Cell to Bus2 n
3. Connect R-CON1 to Bus1 d
4. Connect Bus2 to TRN o
5. Connect Bus1 to TRN q
6. Charge Reactor Containment to 2000As
7. Disconnect RCON-1 from Bus1 d
8. Activate Temperature View Mode Tab
LOOP
9. Connect Reactor Heater x
10. Continue until Fuel Cell temp >= 110C
11. Connect BAT to Bus2 r
12. Continue until BAT temp >= 80C
13. Disconnect Reactor Heater x
14. Wait until Fuel Cell Temp <=80C
15. Repeat LOOP until Reactor Temp=80C OR Reactor Containment < 100As
END LOOP
16. Activate Reactor Injectors 5 , 6
17. Disconnect Battery from Bus2 r
18. Disconnect Fuel Cell from Bus2 n
19. Deactivate Fuel Cell Injector 7

AYSE

1. Connect Battery to BusA F3
2. Connect AYSE Reactor Heater to BusA 0
3. Wait until Reactor Temp=80C
4. Activate Reactor Injectors [ , ]
5. Disconnect Battery from BusA F3

Physics

Nuclear fusion is a high temperature process, and the reactor must be warmed before nuclear reactions can commence. As the reactions begin, it is essential that the reactors are shielded to prevent the astronauts from being irradiated. During the heating process, the reactor is unable to supply any power, so the fuel cell must be used to power both the reactor's shields and the heater.